Containment systems at the intersection of the non rated exterior curtain wall and fire resistance rated floor assemblies.
Exterior curtain wall floor intersection.
Section 714 4 exterior curtain wall floor intersection.
Curtain wall and edge of slab fire barrier systems for single spandrel zero spandrel and steel back pan configurations hilti s vast library of firestop solutions ranging from traditional spandrel designs 100 vision glass or eifs are unrivaled in the industry.
713 4 exterior curtain wall floor intersection.
Although local codes may vary generally fire resistance rated floor ceiling assemblies are required in construction types i a i b ii a iii a and v a.
Perimeter fire containment systems must be tested.
Where fire resistance rated floor or floor ceiling assemblies are required voids created at the intersection of the exterior curtain wall assemblies shall be sealed with an approved system to prevent the interior spread of fire.
Where fire resistance rated floor or floor ceiling assemblies are required voids created at the intersection of the exterior curtain wall assemblies and such floor assemblies shall be sealed with an approved system to prevent the interior spread of fire 715 4 1.
Nyc building code 2014 7 fire and smoke protection features 714 fire resistant joint systems 714 4 exterior curtain wall floor intersection.
Voids created at the intersection of exterior curtain wall assemblies and nonfire resistance rated floor or floor ceiling assemblies shall be sealed with an approved material or system to retard the interior spread of fire and hot gases between stories.
When fire resistive floor or floor ceiling assemblies are required voids created at the intersection of the exterior wall assemblies and such floor assemblies shall be sealed with an approved material.
Where fire resistance rated floor or floor ceiling assemblies are required voids created at the intersection of the exterior curtain wall assemblies and such floor assemblies shall be sealed with an approved material or system to prevent the interior spread of fire.
Where fire resistance rated floor or floor ceiling assemblies are required.
The void created at the intersection of a floor ceiling assembly and an exterior curtain wall assembly shall be protected in accordance with section 715 4 o 715 4 exterior curtain wall.
714 4 exterior curtain wall floor intersection.