This article applies to the dodge ram 1994 2001.
Evaporator wet floor.
The air conditioner isn t cooling well.
To find out where your leak could be coming from check out the information below.
If you are experiencing water on the passenger side floor of your car or truck and if it s not antifreeze 99 of the time it is a simple fix.
You can prevent slime and eliminate drain tube clogs.
Water on floor passenger side from clogged ac condensate drain.
You turn your a c on crank it to the coldest temperature setting and expect cold air to.
By design water can get into the inside of your car s doors either from rain or from splashing by passing cars on wet roads.
Bacteria from airflow combines with condensation from the ac coil to produce a mildew mold smell and the formation of a slime on the ac fins.
Dirty air filter blocks air over the coil causing the coil to get too cold and freeze up.
This can force water into the.
Condensation from air conditioning coils contains bacteria that can form slime and clog the condensate pan drain tube.
It s caused by bacteria buildup on the ac evaporator coil located in the heater box under your dash.
Over time moisture from the air collects on those coils.
Normally any water that gets into the door will drain out onto the road but the door s drain holes can become clogged too.
As warm air from your home passes over your evaporator coils the refrigerant inside the coils absorbs both heat and moisture from that air.
Similar to a dirty air filter low refrigerant will lower pressure in the ac system causing the evaporator coil to freeze over.
How to replace a c evaporator hot air blowing through your a c vents.
Change the filter and see if that helps.
Our technicians have found three things that most often explain wet interior floor mats and footwells.
A wet floor mat or carpet can develop mold mildew and other odorous issues.
Route it to the floor drain and secure it with tubing straps.
Car smells wet mazda 2 3 5 6 cx 7 cx 9 cx 3 cx 5 cx 3 if you have mazda and your carpet is wet on the pas.
Causes of a wet passenger side floor mat 3.
When you see water puddling around the furnace with the a c running you have a clogged condensate drain tube.
You ll notice you re low on refrigerant when.
When the coil melts water overflows the drain pan.
How to replace a c evaporator.
Connect a wet dry vacuum to the drain exit.
This is one of the more common problems.
You hear a hissing or bubbling noise indicating a refrigerant leak.
So when the ice melts water flows over the drain pan and leaks on to your floor.