Us duct leakage testing ri trequirements smacna duct class 1 2 inwg 3 inwg 4 6 10 inwg seal class cb a sli t transverse joints seams sealing applicable ransverse joints only asvese joints and seams jo s sea s and all wall penetrations leakage class c l cfm leakage per 100 ft2 1 in h 2 o rectangular.
Duct leakage test results.
Testing shall be conducted by an approved third party.
Start a free trial now to save yourself time and money.
In both cases the requirements are the same.
Required 3rd party test for new homes and retrofits according to building codes in the state of illinois a duct pressure test must be performed if any portion of the hvac system is placed in unconditioned spaces such as an attic crawlspace or garage.
Test to as a leakage specifi cation.
Duct leakage testing 2017 dc energy conservation code 2015 iecc r403 3 3 duct testing mandatory.
A duct leakage tester is a diagnostic tool designed to measure the airtightness of forced air heating ventilating and air conditioning hvac ductwork.
Figure 5 1l from the 2012 smacna hvac air duct leakage test manual shows the allowable leakage as a function of duct leakage classification and static pressure in the duct.
Here is an example.
The most secure digital platform to get legally binding electronically signed documents in just a few seconds.
The test results shall be provided to the building official and the homeowner.
Duct systems that are documented to have been previously sealed as confirmed through field verification and diagnostic testing in accordance with procedures in rs 33.
A duct leakage test duct testing can be performed at rough in before drywalling or post construction.
Rough in test less than 4 cfm per 100 sq ft which for my house is about 160 cfm if the air handler is included in the leakage test.
Fill out securely sign print or email your duct leakage test report tra green instantly with signnow.
The system will need to achieve a leakage rate of less than 4 cfm cubic feet per minute per 100 square feet of the home.
The energy final inspection will not be complete without a passing test result.
Leakage class can be calculated using equation 3 but needs to be specified if duct air leakage tests are required.
Ducts with less than 40 linear feet in unconditioned spaces.
Our duct leakage test results are in.
However our local utah code has a carve out allowing 7 cfm per 100 sq ft.
Mcgill airflow often gets specifi cations stating that the leakage class for rectangular and round ductwork will be in accor dance with the smacna table 4 1 for a 3 inch water gauge wg supply duct system thus allowing the rectangular duct leakage class to be 12 and the round and fl at oval duct leakage.
Duct leakage test report.
Available for pc ios and android.
A duct leakage tester consists of a calibrated fan for measuring an air flow rate and a pressure sensing device to measure the pressure created by the fan flow.